The Tocsin 103 Series is available in analogue and addressable version and housed in Mild Steel body with IP66 Ingress protection.

  • 4-Wire addressable technology or 4-20mA Analogue output
  • Ingress Protection IP66
  • Pre-calibrated sensors
  • In-Service Calibration Possible
  • Replaceable Sensor

Power 12-30V DC
Construction Powder Coated Mild Steel
Output

4 Wire Addressable

4-20mA Linear Output for calibrated gas and range

Temperature

Toxic Gases - -5 to 55 Deg C 

Pellistors - 20 to 85 Deg C

Humidity 15-90% RH Non-Condensing
Sealing IP66
Mounting Wall Mount

 

 

T103 Analogue Detectors

Product Code Description
5101601 T103 Analogue Detector - Hydrogen Flouride (HF) - 0-10PPM
5112901 T103 Analogue Detector - Methanol (CH3OH) - 0-200PPM
5130201 T103 Analogue Detector - Carbon Monoxide (CO) - 0-100PPM
5130301 T103 Analogue Detector - Nitric Oxide (NO) - 0-50PPM
5130401 T103 Analogue Detector - Nitrogen Dioxide (NO2) - 0-20PPM
5130501 T103 Analogue Detector - Chlorine (CL2) - 0-5PPM
5130601 T103 Analogue Detector - Hydrogen Sulphide (H2S) - 0-50PPM
5130701 T103 Analogue Detector - Ammonia (NH3) - 0-100PPM
5130702 T103 Analogue Detector - Ammonia (NH3) - 0-1000PPM
5130902 T103 Analogue Detector - Oxygen (02) SPE - 0-25%VOL
5131001 T103 Analogue Detector - Sulphur Dioxide (S02) - 0-5PPM
5131201 T103 Analogue Detector - Hydrogen Chloride (HCL) - 0-100PPM
5131501 T103 Analogue Dectector Infra Red - Hydrocarbon (HC) - 0-100%LEL
5131601 T103 Analogue Detector Infra-Red - Carbon Dioxide (CO2) - 0-5%V/V
5132601 T103 Analogue Detector - Ammonia (NH3) - 0-5000PPM
5137001 T103 4-20mA/Add. Safe Area Detector - Flammable Gases - 0-100%LEL
5137301 T103 Analogue Detector - Formaldehyde (CH20) - 0-5PPM
5137401 T103 Analogue Detector - Ozone (03) - 0-5PPM
5138101 T103 Analogue Detector - Hydrogen Cyanide (HCN) - 0-10PPM
5139401 T103 Analogue Detector - Ethylene (C2H4) - 0-2000PPM
5142601 T103 Analogue Detector - Nitrous Oxide (N2O) - 0-1000PPM
5224601 T103 Analogue Detector - Hydrogen (H2) - 0-100PPM
5224701 T103 Analogue Detector - Ethanol (C2H5OH) - 0-500PPM
5226401 T103 Analogue Detector - F2 - 0-1PPM
5227101 T103 Analogue Detector - ETO - 0-20PPM
5880701 T103 Analogue Detector - Silane (SiH4)
5921501 T103 Analogue Detector - Temp Senor Loop Powered

*We offer sensors for more than 400 gases

T103 Addressable Detectors

Product Code Description
5101601A T103 Add. Detector - Hydrogen Flouride (HF) - 0-10PPM
5130201A T103 Add. Detector - Carbon Monoxide (CO) - 0-100PPM
5130301A T103 Add. Detector - Nitric Oxide (NO) - 0-50PPM
5130401A T103 Add. Detector - Nitrogen Dioxide (NO2) - 0-20PPM
5130501A T103 Add. Detector - Chlorine (CL2) - 0-5PPM
5130601A T103 Add. Detector - Hydrogen Sulphide (H2S) - 0-50PPM
5130701A T103 Add. Detector - Ammonia (NH3) - 0-100PPM
5130702A T103 Add. Detector - Ammonia (NH3) - 0-1000PPM
5130902A T103 Add. Detector - Oxygen (02) SPE - 0-25%VOL
5131001A T103 Add. Detector - Sulphur Dioxide (S02) - 0-5PPM
5131201A T103 Add. Detector - Hydrogen Chloride (HCL) - 0-100PPM
5131501A T103 Add. Dectector Infra Red - Hydrocarbon (HC) - 0-100%LEL
5131601A T103 Add. Detector Infra-Red - Carbon Dioxide (CO2) - 0-5%V/V
5132601A T103 Add. Detector -Ammonia (NH3) - 0-5000PPM
5137301A T103 Add. Detector - Formaldehyde (CH20) - 0-5PPM
5137401A T103 Add. Detector - Ozone (03) - 0-2PPM
5138101A T103 Add. Detector - Hydrogen Cyanide (HCN) - 0-10PPM
5139401A T103 Add. Detector - Ethylene (C2H4) - 0-2000PPM
5142601A T103 Add. Detector - Nitrous Oxide (N2O) - 0-1000PPM
5224601A T103 Add. Detector - Hydrogen (H2) - 0-100PPM
5224701A T103 Add. Detector - Ethanol (C2H5OH) - 0-500PPM
5227101A T103 Add. Detector - ETO - 0-50PPM
5880701A T103 Add. Detector - Silane (SiH4) - 0-10PPM
5921501A T103 Add. Detector - Temp Senor Loop Powered

*We offer sensors for more than 400 gases